TR500L-P Lube

Used For: Engine Oil

CAPACITY & FLOW RATE

  • Requires 12 Qt./11.4 L. of makeup fluid (housing volume)

    • Ideal sump size range from 5-11 Gal./18.9-41.6 L.

    • Flow rate range from 0-1.25 GPM/0-4.7 LPM

SPECIFICATIONS

  • 14.25”(H) Plus 13” clearance above to change filter

  • 10.62”(W)

  • 10.75”(D)

  • Shipping weight: 25 LB

  • Max operating pressure 80 PSI

  • 1/2” FNPT inlet, outlet and drain ports

  • Finish: Powder Coated silver color

    • Powder-coating inside and outside of housing

  • Used with petroleum or synthetic fluids

SPECIFICATIONS

  • Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary

  • Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

  • Most applications, elements need to be changed between 500-1000 hours for optimal performance, ideally change the element when the flow is half the starting flow or the PSI is double the starting PSI

  • Available option for water-based lubricants & hydraulic lubricants

RECOMMENDED VISCOSITIES

  • Model TR5002 for SAE: 20, 30, 40

  • Model TR5004 for SAE: 50

    • Trinity is able to meet a variety of requirements, please contact us with your specific custom needs.

MAGMICRON TECHNOLOGY

  • Charged polarity source + 1 micron filter element provides unequaled oil & fuel purification

  • Removes water and acid buildup

  • Extends engine life 3X

  • Reduces maintenance costs 85%

  • Reduces oil service 4X

  • Reduces engine rebuild by 67%

  • Reduces hydrocarbon emissions

Previous
Previous

Trinity Fuel Conditioner

Next
Next

TR500H-P Hydraulic