OIL & FUEL PRODUCTS

WATER-BASED COOLANT & EDM PRODUCTS

OIL & FUEL
PRODUCTS

THE TRINITY RSS OIL & FUEL CONDITIONING AND FILTERING SYSTEMS COMBINE THE MAGNETIC EFFECTS OF CONDITIONING HYDROCARBONS WITH A MAGNETICALLY ENHANCED 1-MICRON FILTERING ELEMENT PRODUCING AN UNMATCHED CAPABILITY IN EQUIPMENT PERFORMANCE, LIFE, WEAR ON PARTS, AND REDUCING OIL AND FUEL USE, AND EMISSIONS. THE UNIQUE COMBINATION OF CONDITIONING AND FILTERING IS UNEQUALED IN THE LUBRICATION INDUSTRY.

Commercial TR1000 Oil/Fuel Filter

 USED FOR ALL PETROLEUM OR SYNTHETIC FLUID LUBRICATED SYSTEMS (E.G., HYDRAULIC OIL, ENGINE OIL, TRANSMISSION OIL, DIESEL FUEL, GEAR OIL)

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

    Gear Boxes

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

Industrial Double Stack TR1000s Oil/Fuel Filters

USED FOR ALL PETROLEUM OR SYNTHETIC FLUID LUBRICATED SYSTEMS (E.G., HYDRAULIC OIL, ENGINE OIL, TRANSMISSION OIL, DIESEL FUEL, GEAR OIL)

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

TR150 Wind Turbine Configuration

USED FOR ALL PETROLEUM OR SYNTHETIC FLUID LUBRICATED SYSTEMS (E.G., HYDRAULIC OIL AND GEAR OIL)

  • Hydraulic Oil

    Gear Boxes

    Bearings (oil-based)

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary.

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment.

TR3520 Generator Engine

USED FOR ENGINE OIL

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

  • CAPACITY & FLOW RATE

    • Requires 80 Qt./75.71 L. of makeup fluid (housings volume)

    • *Ideal sump size range from 64-88 Gal./242-333 L.

    • **Flow rate range from 0-8 GPM/0-30.3 LPM

    OVERALL DIMENSIONS & WEIGHT

    • 44” (H) Plus 20” clearance above to change filter

    • 24” (W)

    • 26” (D)

    • 220 LB. shipping weight OTHER SPECIFICATIONS

    • Max operating pressure 80 PSI

    • 1/2” Female NPT inlet, outlet & drain ports

    • Used with petroleum or synthetic fluids

TR3516 Generator Engine

USED FOR ENGINE OIL

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

  • CAPACITY & FLOW RATE

    • Requires 60 Qt./56.78 L. of makeup fluid (housing volume)

    • *Ideal sump size range from 48-66 Gal./181.7-2.49.8 L. z

    • **Flow rate range from 0-6 GPM/0-22.7 LPM

    OVERALL DIMENSIONS & WEIGHT

    • 44” (H) Plus 20” clearance above to change filter

    • 24” (W)

    • 26” (D)

    • 191 LB. shipping weight

    OTHER SPECIFICATIONS

    • Max operating pressure 80 PSI

    • 1/2” Female NPT inlet, outlet & drain ports

    • Used with petroleum or synthetic fluids

TR1200P Filter

USED FOR HYDRAULIC OIL, TRANSMISSION OIL, CUTTING OIL, OTHER OIL-BASED LUBRICANTS, DIESEL FUEL

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

  • • 43.5”(H) Plus 25” clearance above to change filter

    • 16.75”(W)

    • 16.75”(D)

    • Shipping weight: 128 LB

    • Max operating pressure 125 PSI

    • 1 1/2” FNPT inlet, outlet and drain ports

    • **Powder-coating inside and outside of housing

    • Used with petroleum or synthetic fluids & diesel fuel

Commercial TR150 Oil/Fuel Filter Engines

USED FOR ALL PETROLEUM OR SYNTHETIC FLUID LUBRICATED SYSTEMS (E.G., HYDRAULIC OIL, ENGINE OIL, TRANSMISSION OIL, DIESEL FUEL, GEAR OIL)

  • Engines

    Diesel Fuel Engines

    Generators

    Heavy Machinery

    Turbines

    Compressors

    Gear Boxes

    Data Center Servers (dielectric fluids)

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

TR125, TR71, TR61 Spin-On Oil/Fuel Filter

USED FOR ALL PETROLEUM OR SYNTHETIC FLUID LUBRICATED SYSTEMS (E.G., HYDRAULIC OIL, ENGINE OIL, TRANSMISSION OIL, DIESEL FUEL, GEAR OIL)

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

    Gear Boxes

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at

    the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated

    contamination will affect sizing and flow rates of filtration equipment

Fuel Conditioner

USED FOR ALL PETROLEUM OR SYNTHETIC FLUID LUBRICATED SYSTEMS (E.G., HYDRAULIC OIL, ENGINE OIL, TRANSMISSION OIL, DIESEL FUEL, GEAR OIL)

  • Engines

    Diesel Fuel

    Biomass Fuels

    Generators

    Refrigerants

    All hydrocarbon-run systems

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at

    the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

TR500 Lube & Hydraulic Filter

HYDRAULIC OIL, TRANSMISSION OIL, CUTTING OIL, OTHER OIL-BASED LUBRICANTS, DIESEL FUEL

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

    Gear Boxes

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

Single-Dual Housing Portable Hydraulic

HYDRAULIC OIL, TRANSMISSION OIL, OTHER LOW VISCOSITY OIL, USE WITH PETROLEUM OR SYNTHETIC FLUIDS

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

    Gear Boxes

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

Water Glycol Filter

WATER GLYCOL FLUIDS, OTHER OIL-BASED LUBRICANTS

  • Engines

    Diesel Fuel Engines

    Generators

    Turbines

    Compressors

    Gear Boxes

  • Max operating pressure, 80 PSI

    1/2” ORB inlet, outlet & drain ports

    Requires 4 Qt./3.8 L. of makeup fluid (housing volume)

    Ideal sumps range from 0-4 Gal./0-15.1 L.

    Flow rate ranges from 0-.7 GPM/2.6 LPM

    **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary

    *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment

Dielectric Fluid Filter

DIELECTRIC OIL, DATA CENTER AND CRYPTO MINING SERVER IMMERSION FLUIDS (MINERAL OIL, FR3, ETC.), LOAD TAP CHANGER OIL, TRANSFORMER OIL

  • • Requires 20 Qt./18.9 L. of makeup fluid (housing volume)

    • Oil sump range: 0-300 Gal./0-1135.6 L.

    •**Flow rate range for transformer oil from 0-3 GPM/0-11.4 LPM

  • • *3 GPM 65 PSI pump (not fluid flow rate)

    • 1/2 HP 1725 RPM washdown motor

    • 120 volt, single phase

    • No power cord included

    • Pressure gauge NEW go-no-go gauge for indicating element

    • No hoses included

    • System fittings -Suction system end-3/4” FNPT - Discharge system end-1/2” FNPT

    • Max operating pressure 80 PSI

THE CONDITIONER BETTER PREPARES THE FUEL FOR COMBUSTION BY COMBINING THE CHARGED POLARITY SOURCE OR CONDITIONER AND THE FILTERING UNIT. AS A RESULT, BETTER COMBUSTION INCREASES PERFORMANCE AND EFFICIENCY WITH FEWER EMISSIONS. IN ADDITION, IT REDUCES PARTICLES BLOWING PAST PISTON RINGS AND SEALS INTO THE CRANKCASE, GREATLY ENHANCING THE ABILITY OF THE REFINING ELEMENT TO ADSORB PARTICLES AND ABSORB WATER.

FILTERING ELEMENTS

THE TRINITY ELEMENT REMOVES CONTAMINANTS AS LOW AS 1 MICRON AND PARTICLES FROM WATER-BASED COOLANTS WHILE NOT DELETING ADDITIVES.

Oil and Fuel Element

USED FOR ALL OIL-BASED APPLICATIONS

  • Down to 1-micron

    100% effectiveness after 6-7 cycles

    Removes water

    Optimum replacement every 500 hours but can last up to 1000 hours

    Heavy contamination or older equipment may require more frequent changes if the system was not flushed out prior to installation

    If installed on older or un-refurbished equipment the product will not reduce already existing wear but will significantly limit further wear


TR1000 Series Elements

Overall Dimensions: 7.5” dia. x 19.75” lg

Two Section TR1002

Designed to filter hydraulic and lube oils in systems on industrial equipment, heavy equipment, transmission and large diesel engines. For Viscosity of ISO 10–32 & diesel fuel

SAE 5w, 10w, 15w

Four Section TR1004

Designed to filter fluids in systems on industrial equipment, heavy equipment, transmission and large diesel engines. For Viscosity of ISO 46–150 SAE 20, 30, 40

Six Section TR1006

Designed to filter oil-based EDM fluids, gear and high viscosity oils. For Viscosity of ISO 220–320 SAE 50

Eight Section TR1008

Designed to filter gear oils and very heavy viscosity oils. For Viscosity of ISO 460–1000


Two Section TR5002

Designed to filter engine oil or fluids in systems on industrial equipment, small mobile equipment, and transmissions.

For Viscosity of ISO 46–150 & diesel fuel

SAE 5w, 10w, 15w, 20, 30, 40

Four Section TR5004

Designed to filter gear oils and very heavy viscosity oils.

For Viscosity of ISO 460–1000

SAE 50

Two Section TR1502

Designed to filter engine oil and fluids in systems on industrial equipment.

For Viscosity of ISO 10–150

Diesel Fuel & SAE 5w, 10w, 15w, 20, 30, 40

Four Section TR1504

Designed to filter engine oil and fluids in systems on industrial equipment. For Viscosity of ISO 220–1000. SAE 50



1000 SERIES: 7.50” DIA. X 19.75” LG.

  • TR1002WG

    Designed for light glycol mixtures

  • TR1004WG

    Designed for higher flow rates and to filter light glycol mixtures.

  • TR1006WG

    Designed for high glycol mixtures.

1200 Series: 11” dia. x 15.25” lg.

  • TR1202WG

    Designed for light glycol mixtures

  • TR1203WG

    Designed for higher flow rates and to filter light glycol mixtures.

  • TR1204WG

    Designed for high glycol mixtures.

500 Series 7.50” dia. x 10” lg.

  • TR5002WG

    Designed to filter water-based fluids, coolants, light glycol mixtures and water-based EDM fluids.

3902 Water Glycol Element

USED FOR ALL WATER-BASED LUBRICANTS AND WATER GLYCOL FLUIDS

  • Down to 1-micron

    100% effectiveness after 6-7 cycles

    Optimum replacement every 500 hours but can last up to 1000 hours

    Heavy contamination may require more frequent changes if the system was not flushed out prior to installation

TR500 Series Elements

Overall Dimensions: 7.5” dia. x 10.06” lg

TR150 Series Elements

Overall Dimensions: 5.50” dia. x 8.81” lg

TR1200 Series Elements

Two Section TR1202

Dimensions: 11.0” dia. x 15.25” lg. Designed to filter lighter viscosity fluids such as diesel fuel and light viscosity hydraulic oils up to

ISO 10–32 & diesel fuel. SAE 5w, 10w, 15w

Three Section TR1203

Dimensions: 11.0” dia. x 10.25” lg.

Designed to filter lighter viscosity fluids such as Diesel fuel and light viscosity hydraulic oils up to ISO 46–68 & diesel fuel. SAE 20

Four Section TR1204

Dimensions: 11.0” dia. x 15.25” lg.

Designed to filter fluids in large diesel engines and systems

on industrial equipment, heavy equipment, and transmissions. For viscosity of ISO 100–150.

SAE 30, 40

Water Based Elements

Designed to filter water-based fluids, coolants, and water-based EDM fluids

Specifications:

Maximum operating pressure: 80 psi Flow rate: SAE 30 @ 180 ̊F: .5 GPM Mounting base kit required for spin-on filters sold separately.

TR61

TR71 Brochure

TR125 Brochure

**Bypass filters and should not be confused with full-flow filters. Spin-on elements are not changed as often as full-flow filters and are changed separately. Equipment not required to be shut down during Spin-on element changes.


Spin-On Elements

Trinity RSS “Spin-On” filters provide filtration for light industrial applications, cars, campers, vans, trucks, and tractors.

WATER-BASED COOLANT & EDM
PRODUCTS

The Trinity System, designed for water-based coolant and EDM products, excels in removing impurities through its unique combination of fluid conditioning and filtering. The TRSS filter element removes impurities down to 1 micron while the fluid conditioner eliminates the necessity for chemical or inhibitor usage in combating biofouling buildup, resulting in operator cost savings and promoting environmentally friendly practices.

Machine-Tool Coolant

Extend Coolant Life and Maximize Productivity

Water-Glycol Hydraulic Fluid

Extend Water-Glycol Life and Reduce Machine Downtime

Water-Glycol Coolant

Remove Particulate and Tramp Oil Contamination to Extend Fluid Life